Electrical Products & Services
Start spacing at half the ceiling height; plan ambient, task and accent lighting, match housings/optics and verify ratings before cutting.

Start recessed lighting spacing at half the ceiling height, then adjust for the room and fixture. For a 2.4 m (8 ft) ceiling, that means roughly 1.2 m (4 ft) between lights and 0.6 m (2 ft) from walls – but only as a starting point for general lighting.
A workable plan also needs to:
Before installation, an Ontario Licensed Electrical Contractor should check wiring, clearances and ESA notification and inspection requirements. The room’s use – not a ceiling grid – should guide the final layout.

Recessed Lighting Spacing and Layout Checklist
Once spacing is set, give each fixture a job: ambient, task or accent lighting. Map work surfaces, furniture and focal points before deciding where fixtures go.
| Lighting layer | Purpose | Placement approach | Common layout risk |
|---|---|---|---|
| Ambient | General lighting | Even coverage | Dark edges or hot spots |
| Task | Light work surfaces | Align with work areas | User shadows |
| Accent or wall wash | Highlight a target surface | Match target and optics | Glare or uneven coverage |
Place kitchen downlights over the active counter area, not behind the person preparing food. Plan their positions around sinks, appliances and upper cabinets. If cabinets block the beam, use under-cabinet lighting rather than adding another downlight.
Centre island lights over the island, not the aisle. At desks and retail counters, check for monitor glare and shadows cast by the user. Use side lighting where overhead fixtures would cast shadows. At vanities, side lights help reduce facial shadows.
Next, move from horizontal work surfaces to vertical surfaces.
Choose the wall-wash optic first. Then match the fixture’s distance from the wall and spacing to its beam. Check coverage on the target surface: fixtures too close to the wall can create harsh scallops, while uneven spacing can leave bright and dark patches. Use adjustable accent lights for artwork or merchandise.
Put ambient, task and accent lighting on separate switches or dimmers. Check that the LEDs and dimmers are compatible, and place controls within easy reach near common entry points.
With the layout mapped, match the housings, trims and LED output to the ceiling conditions.
Once you’ve mapped the spacing, match the fixture to the ceiling assembly. Housing type, insulation rating, location rating and trim function are separate choices. Check ceiling depth, thickness and access before ordering. Even canless fixtures need room for the driver and junction box, along with access for servicing.
| Selection | Typical application | Main check |
|---|---|---|
| New-construction housing | Open framing before ceiling finishes | Mounting access and cavity dimensions |
| Remodel housing | Existing finished ceilings | Opening size and available cavity |
| Canless LED luminaire | Ceilings without a separate recessed can | Driver space, access and product ratings |
| Insulation-contact rating | IC permits insulation contact as marked; non-IC requires separation | Permitted contact and specified clearances |
| Fixed trim | General downlighting | Beam distribution and glare |
| Adjustable or gimbal trim | Sloped ceilings or targeted lighting | Aiming range and shielding |
| Wall-wash trim | Walls and vertical displays | Optic-specific offsets and spacing |
IC, airtight and fire-resistance suitability mean different things. An IC rating does not automatically allow contact with spray foam. If the ceiling needs an air seal, choose an airtight or appropriately air-sealed product and install it as instructed. For a fire-rated ceiling, check that the product suits that assembly. Match dry-, damp- or wet-location ratings to the actual exposure – a damp rating cannot replace a wet rating.
Look for a Canadian certification mark, such as CSA or cUL, on the complete luminaire or kit, not just the driver. Check that the housing, trim and module work together. Installation must follow product markings, manufacturer instructions and Ontario electrical requirements. Before rough-in, use your planned spacing and wall offsets to check that the housing fits the ceiling.
Compare delivered lumens and beam distribution, not wattage alone. Aperture size doesn’t tell you how bright a fixture will be. Ceiling height, surface reflectance and beam spread also affect coverage. Check the photometric data for beam shape and glare control. A deeper light source, baffle or shielding can reduce direct glare, especially when the aperture is in direct view.
Choose 2700–3000 K for living areas, 3000–3500 K for kitchens and offices, and 4000 K for task-heavy commercial spaces. Consider CRI 90 or higher where colour accuracy matters. Keep colour appearance consistent across connected spaces, and record any selectable settings.
Test the exact LED-and-dimmer combination for flicker, buzzing, low-end shutdown and start-up performance. Then check the maximum fixture count and minimum load.
Use your selections to mark the openings and check the layout before cutting into the ceiling.
Test the final layout on paper and on site before cutting. Draw the room to scale, including ceiling height, fixed features and work zones. Mark fixture centres, wall offsets, beam aim and control zones. Use your spacing and layer plan to check coverage in each lighting zone, including where beams overlap on target surfaces. In commercial spaces, use manufacturer photometrics to verify average and minimum illuminance. Spacing alone isn’t enough.
Mark proposed fixture centres on the ceiling with painter’s tape or a laser. Check sightlines while sitting, standing and working at counters. Look for body shadows, exposed light sources and dark edges. Check fixture positions against cabinets, ceiling fans, HVAC diffusers, sprinklers and smoke alarms, leaving all required clearances. Do not move life-safety devices just to keep a lighting grid.
Once the layout works for the room, check that the ceiling can accommodate it.
Before cutting, check the ceiling structure and electrical path. Map joists, ducts, plumbing and existing wiring before confirming cut-out locations. Check cavity clearance and access to drivers and junction boxes. Protect the air barrier, vapour barrier and any required fire-rated assembly at every opening. Do not cut structural members or leave ceiling barriers unsealed.
Have an Ontario Licensed Electrical Contractor assess circuit loading, conductor size, cable routes, switching arrangement, dimmer compatibility and control zones. Confirm applicable Electrical Safety Authority (ESA) notification and inspection requirements before work starts, including any inspection required before wiring is concealed. Keep fixture instructions and the final marked plan on site.
A centre-only grid can put too much light in the middle while missing counter edges and leaving the perimeter dark. Address counter shadows, wall scallops and glare before cutting.
Don’t base the layout on ceiling height alone, skip separate control zones or overlook colour and dimming compatibility. Recheck ratings and clearances, then mark each opening from fixed reference points.
At this stage, check your plan rather than redesign it. Use ceiling-height spacing as a starting point only. Let task zones, the fixture’s photometric data and ceiling constraints guide final placement.
Before cutting openings, bring your room drawing, fixture specifications and ceiling details to Draper Electric for a final layout check. The company provides residential and commercial electrical installations across the Ottawa Valley.
Start with the room’s dimensions, how you’ll use it and the mood you want to create. Task lighting suits workspaces, while ambient lighting provides general illumination. Ceiling height also affects how light spreads and how far apart fixtures should be placed.
Draper Electric serves the Ottawa Valley, helping plan and safely install efficient lighting layouts with the right power supply. Its team handles residential and commercial renovations and new construction, with layouts that meet local codes.
Space recessed lights to spread light evenly across the floor. Use housings and trims designed for sloped ceilings so fixtures sit vertically and direct light downward, rather than at an angle. This helps prevent glare and keeps lighting even.
Placement and installation need to be precise to meet safety and layout standards. Draper Electric offers professional installation across the Ottawa Valley.
Yes, but only if the circuit has enough capacity left. At 80% capacity, a 15-amp circuit supports 1,440 watts, while a 20-amp circuit supports 1,920 watts. Add the wattage of all existing devices and fixtures to the wattage of the new lights to avoid overloading the circuit.
Contact a professional at Draper Electric to check the load calculations and wiring, and confirm that the installation meets safety codes and load requirements.